Name of Equipment |
LABTOP® Micro controller (PID) based Stability Test Chamber |
Air Circulation |
Motor and blower arrangement to have uniformity of Temperature under loaded condition. ( 2 blowers for 400 Liters and above) |
Alarm |
Audio Visual Alarm if the temperature deviates from the preset temperature |
Trays |
Stainless Steel trays. |
Lighting |
Interior illumination for working area. |
Insulation |
3” Thick CFC free PUF Insulation. |
Heating System |
U shaped S.S. Nichrome wire air heaters. |
Observation Door |
Inside see through unbreakable acrylic door |
Refrigeration System |
Hermetically Sealed CFC Free Emerson Compressor with R 134a refrigerant having state of art by pass system for continues run of compressor. |
Humidity System |
Non condensing type steam injection system with water level arrangement with insulation to save heat energy. |
Control System |
Precise control of temperature and humidity by using CE approved micro controller based PID controller (Auto tuning type) |
Validation Port |
50 mm validation Port with silicon rubber seal to insert sensor for validation purpose. |
Power |
Works on 230 V AC single phase 50Hz |
Other |
Castor wheels, MCB, Adjustable Tray Height arrangements. Heavy duty latch with lock & key |
Safety Features |
1. Float switch to cutoff the mains supply in case of low water level in the boiler tank.2. Dedicated safety controller with separate sensor to cut off the supply in case of overshoot and undershoot of Temperature giving audio visual alarm.3. Additional safety thermostat to cut off the boiler system in case of overshoot of temperature.4. 180 Sec. compressor ‘ON’ delay timer to safe guard the compressor. |
Certifications |
ISO 9001: 2008 , ISO 13485 : 2012 and CE |
Documentations |
LABTOP will provide IQ, OQ, PQ documents with material test certificates and calibration reports |
SPECIFICATION
Temperature Range |
20 to 60° C |
Temperature Accuracy |
± 0.2° C |
Temperature Uniformity |
2° C |
Humidity Range |
40 to 98% RH. |
Humidity Accuracy |
± 2% RH. |
Humidity Uniformity |
± 3% RH. |
Alarm |
Audio-Visual Alarm. |
Standard Models: Inner Stainless steel 304, 0.8 mm & Outer mild steel,1.0 mm powder coated
Cat.Number |
Capacity In liters |
Internal Size in (WxDxH) cms |
External Size in(WxDxH) cms |
No. of Doors |
No. of trays |
LSC- 100 |
100 |
43x40x60 |
58x72x129 |
Single |
2 |
LSC- 200 |
200 |
50x40x100 |
65x72x169 |
Single |
3 |
LSC- 300 |
300 |
56x45x120 |
71x77x189 |
Single |
4 |
LSC- 400 |
400 |
63x53x120 |
78x85x189 |
Single |
4 |
LSC-600 |
600 |
72x65x130 |
87x97x192 |
Single |
4 |
LSC-800 |
800 |
112x60x120 |
137x92x192 |
Double |
8 |
LSC-1000 |
1000 |
115x67x130 |
140x99x192 |
Double |
8 |
LSC-1500 |
1500 |
130x89x130 |
155x121x192 |
Double |
8 |
LSC-2000 |
2000 |
150x103x130 |
175x135x192 |
Double |
8 |
GMP Models: Inner Stainless steel 304, 0.8 mm & Outer Stainless steel,1.0 mm
Cat.Number |
Capacity In liters |
Internal Size in (WxDxH) cms |
External Size in(WxDxH) cms |
No. of Doors |
No. of trays |
LSC- 100 |
100G |
43x40x60 |
58x72x129 |
Single |
2 |
LSC- 200 |
200G |
50x40x100 |
65x72x169 |
Single |
3 |
LSC- 300 |
300G |
56x45x120 |
71x77x189 |
Single |
4 |
LSC- 400 |
400G |
63x53x120 |
78x85x189 |
Single |
4 |
LSC-600 |
600G |
72x65x130 |
87x97x192 |
Single |
4 |
LSC-800 |
800G |
112x60x120 |
137x92x192 |
Double |
8 |
LSC-1000 |
1000G |
115x67x130 |
140x99x192 |
Double |
8 |
LSC-1500 |
1500G |
130x89x130 |
155x121x192 |
Double |
8 |
LSC-2000 |
2000G |
150x103x130 |
175x135x192 |
Double |
8 |
OPTIONAL ACCESSORIES
SC-10 |
Dedicated Safety system to shut off the air heater in case of over shoot of Temperature, giving audio visual alarm. |
PCI-2 |
PC Interface communication card with RS – 485 for temperature And humidity control system (Hardware for each chamber) |
DB-100 |
Data Bank to record, store and Print set values, process values, Date & time of master controllers with variable print time intervals. |
DS-44 |
4 point temperature and 4 point humidity scanner complete with sensors printer interface and facility to record, store and Print process values, Date & time with variable print time intervals. |
DS-88 |
8 channel temperature and 8 channel humidity scanner complete with sensors printer interface and facility to record, store and Print process values, Date & time with variable print time intervals. |
LW-21 |
“LABTOPWARE” CFR 21 Part 11 compliance Windows based communication software for data management. Complete with RS-485 multi dropping to monitor multiple chambers to one software |
SR-100 |
Ready to use stand by refrigeration system in case of regular system fails. Complete with compressor condenser, evaporator and other accessories with gas charging.(Above 600 Liters) |
SH-1 |
Ready to use stand by Humidity System in case of regular system fails. |
AT-1 |
Additional tray suitable for above equipment |
GSM-5 |
Mobile alert via GSM Technology in case of system failure |
PLC-20 |
Programmable Logic controller (PLC) with built in PID controller ( Auto tune type), data storage, Safety controller, auto changeover of Standby systems & other event Managements and Ethernet connectivity with 3.8” HMI with color touch screen |
BB-8 |
Online uninterrupted power supply for PLC |
DV- 8 |
Validation charges per day (8 hrs) |
Reviews
There are no reviews yet.